Question 58
QMED04The main feed check valve functions to __________.
AI Explanation
The Correct Answer is B.
The main feed check valve is a non-return valve installed between the feed line and the boiler drum (or economizer inlet). Its primary function is safety and operational integrity. It is crucial to **prevent the high-pressure water and steam within the boiler from flowing back into the feed line** and potentially damaging the feed pump or other components in the feed system, especially if the feed pump stops running (fails) or loses discharge pressure.
### Why other options are incorrect:
**A) reduce feed pump discharge pressure loading:** The check valve introduces a slight pressure drop, but its main purpose is not to manage or reduce the overall discharge pressure loading on the pump. Pressure reduction is typically handled by regulating valves or line resistance.
**C) check pressure pulsations in the feed line:** While valves and fittings influence flow, specialized components like dampeners are used to manage significant pressure pulsations. The feed check valve's primary role is flow direction control (non-return), not pulsation damping.
**D) provide feed pump positive discharge head:** The feed pump itself generates the discharge head necessary to overcome boiler pressure. The check valve is installed *after* the pump and relies on the pump's generated pressure to open. It does not actively contribute to the pump's positive discharge head; rather, it protects the system from reverse flow.
Related Questions
#56 The DC heater automatic level dump valve is used to __________.#57 Why is it important for double bottom fuel oil tanks not to be topped off when loading fuel at cold
temperatures?#59 With regard to the number of passes through the tubes of shell-and-tube heat exchangers, what statement is
true?#60 Which of the following labeled items of the illustrated section of boiler refractory represents the insulating
block? Illustration SG-0003#61 According to the illustrated steam tables, what would be the superheater outlet temperature if saturated steam
at 400 psia was elevated 192.83°F? Illustration SG-0004